Sürdürülebilir Kalkınma Amaçları

  • MakaleAçık Erişim2026Scopus SJRQ2
    Which implant for Pauwels type 2 femoral neck fractures: a biomechanical study

    Aydın, Oğuz; Kazez, Muhammed; Say, Yakup; Belhan, Oktay

    Objective: Femoral neck fractures (FNF) in young patients are relatively rare but can lead to severe complications if not treated appro-priately. Pauwels type 2 fractures, characterized by moderate inclination, require surgical stabilization. However, no consensus exists regarding the optimal implant that provides superior biomechanical stability. This study aims to compare the biomechanical properties of 3 different fixation systems for the surgical treatment of Pauwels type 2 FNF. Methods: A total of 21 bovine femurs of similar age and size were selected and divided into 3 fixation groups: dynamic hip screw (DHS), cannulated screws (CS), and major plate (MP). Each specimen underwent axial compression testing to assess the maximum load-bearing capacity, shear force resistance, and deformation characteristics of the fixation methods. Results: The results showed that the CS group exhibited the highest shear stress resistance, followed by the DHS group, while the MP group showed significantly lower mechanical strength and elongation (P <.05). Although DHS provided substantial stability, CS demon-strated superior overall mechanical performance. In contrast, the MP system showed significantly lower resistance compared to the other 2 fixation methods. Conclusion: This biomechanical study highlights the importance of implant selection in the management of Pauwels type 2 FNF. Although previous investigations have questioned the adequacy of CS fixation in highly unstable Pauwels type 3 fractures, the results suggest that CS may be a reliable and effective option for the relatively more stable Pauwels type 2 pattern. Because the tests were performed on bovine femur models, which do not fully reflect the structural characteristics of human bone, these findings should be interpreted with caution. Further biomechanical studies using human cadaveric specimens are required to confirm the applicability of these results to clinical practice.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
  • MakaleYayıncıda açık erişim2022Scopus SJRQ2
    A biomechanical study: Comparison of three different implant options in high Tibial osteotomy

    Key, Sefa; Demir, Sukru; Aydın, Oğuz; Say, Yakup; Erten, Mehmet

    Background: Many implant options could be preferable for fixation after osteotomy in varus knee medial compartment arthrosis. Due to usage characteristics, it is important to compare the biomechanical properties of them. For this purpose, we aimed to examine three different implant types biomechanically in our study. Methods: Ovine tibiae undergoing medial open-wedge high tibial osteotomy were fixed in vitro with three different implants using an angular wedge plate, a metal block plate and an external fixator system. The fixed ovine tibiae were subjected to axial tensile, axial loading and three-point bending tests in a test machine. All biomechanical tests were repeated five times, the maximum and minimum values were ignored, and the average values of the remaining three test results were taken into account. The test results were interpreted after converted into force-elongation curves in Trapezium-X software. Findings: Biomechanical test results revealed some differences between implant types. While the metal block plate had the highest axial tensile strength value, it was the fixation group showing the lowest strength in axial load tests. The used fixator system was the highest strength in axial load tests and the lowest strength in axial tensile tests. Interpretation: Considering the clinically significant forces related to the biomechanical stability of the three different implants used for high tibial osteotomy, the fixator system would appear to be slightly superior, although it should be noted that torsional forces, as well as parameters that could change in living tissue, might affect the results.