Which implant for Pauwels type 2 femoral neck fractures: a biomechanical study

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Objective: Femoral neck fractures (FNF) in young patients are relatively rare but can lead to severe complications if not treated appro-priately. Pauwels type 2 fractures, characterized by moderate inclination, require surgical stabilization. However, no consensus exists regarding the optimal implant that provides superior biomechanical stability. This study aims to compare the biomechanical properties of 3 different fixation systems for the surgical treatment of Pauwels type 2 FNF. Methods: A total of 21 bovine femurs of similar age and size were selected and divided into 3 fixation groups: dynamic hip screw (DHS), cannulated screws (CS), and major plate (MP). Each specimen underwent axial compression testing to assess the maximum load-bearing capacity, shear force resistance, and deformation characteristics of the fixation methods. Results: The results showed that the CS group exhibited the highest shear stress resistance, followed by the DHS group, while the MP group showed significantly lower mechanical strength and elongation (P <.05). Although DHS provided substantial stability, CS demon-strated superior overall mechanical performance. In contrast, the MP system showed significantly lower resistance compared to the other 2 fixation methods. Conclusion: This biomechanical study highlights the importance of implant selection in the management of Pauwels type 2 FNF. Although previous investigations have questioned the adequacy of CS fixation in highly unstable Pauwels type 3 fractures, the results suggest that CS may be a reliable and effective option for the relatively more stable Pauwels type 2 pattern. Because the tests were performed on bovine femur models, which do not fully reflect the structural characteristics of human bone, these findings should be interpreted with caution. Further biomechanical studies using human cadaveric specimens are required to confirm the applicability of these results to clinical practice.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1502Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.5152/j.aott.2026.25345Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydın, Oğuz
dc.contributor.authorKazez, Muhammed
dc.contributor.authorSay, Yakup
dc.contributor.authorBelhan, Oktay
dc.date.accessioned2026-10-28T14:54:16.790153789Z
dc.date.available2026-10-28T14:54:16.790153789Z
dc.date.issued2026
dc.description.abstractObjective: Femoral neck fractures (FNF) in young patients are relatively rare but can lead to severe complications if not treated appro-priately. Pauwels type 2 fractures, characterized by moderate inclination, require surgical stabilization. However, no consensus exists regarding the optimal implant that provides superior biomechanical stability. This study aims to compare the biomechanical properties of 3 different fixation systems for the surgical treatment of Pauwels type 2 FNF. Methods: A total of 21 bovine femurs of similar age and size were selected and divided into 3 fixation groups: dynamic hip screw (DHS), cannulated screws (CS), and major plate (MP). Each specimen underwent axial compression testing to assess the maximum load-bearing capacity, shear force resistance, and deformation characteristics of the fixation methods. Results: The results showed that the CS group exhibited the highest shear stress resistance, followed by the DHS group, while the MP group showed significantly lower mechanical strength and elongation (P <.05). Although DHS provided substantial stability, CS demon-strated superior overall mechanical performance. In contrast, the MP system showed significantly lower resistance compared to the other 2 fixation methods. Conclusion: This biomechanical study highlights the importance of implant selection in the management of Pauwels type 2 FNF. Although previous investigations have questioned the adequacy of CS fixation in highly unstable Pauwels type 3 fractures, the results suggest that CS may be a reliable and effective option for the relatively more stable Pauwels type 2 pattern. Because the tests were performed on bovine femur models, which do not fully reflect the structural characteristics of human bone, these findings should be interpreted with caution. Further biomechanical studies using human cadaveric specimens are required to confirm the applicability of these results to clinical practice.
dc.identifier.articlenumber0345
dc.identifier.doi10.5152/j.aott.2026.25345
dc.identifier.eissn2589-1294
dc.identifier.endpage7
dc.identifier.issn1017-995X
dc.identifier.issue2
dc.identifier.pmcidPMC13295213
dc.identifier.pmid42364236
dc.identifier.scopus2-s2.0-105044007451
dc.identifier.startpage1
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1502
dc.identifier.volume60
dc.identifier.wosWOS:001851462700001
dc.language.isoen
dc.publisherAVES
dc.relation.ispartofActa Orthopaedica et Traumatologica Turcica
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBiomechanics
dc.subjectCannulated screw
dc.subjectDynamic hip screw
dc.subjectMajor plate
dc.subject.classificationOrthopedics
dc.subject.otherAnimals
dc.subject.otherBiomechanical Phenomena
dc.subject.otherBone Plates
dc.subject.otherBone Screws
dc.subject.otherCattle
dc.subject.otherFemoral Neck Fractures
dc.subject.otherFracture Fixation, Internal
dc.subject.otherHumans
dc.subject.otherProximal Femoral Fractures
dc.subject.otherStress, Mechanical
dc.subject.otheranimal
dc.subject.otherbiomechanics
dc.subject.otherbone plate
dc.subject.otherbone screw
dc.subject.otherbovine
dc.subject.othercomparative study
dc.subject.otherdevices
dc.subject.otherfemoral neck fracture
dc.subject.otherhuman
dc.subject.othermechanical stress
dc.subject.otherosteosynthesis
dc.subject.otherprocedures
dc.subject.otherproximal femur fracture
dc.subject.othersurgery
dc.titleWhich implant for Pauwels type 2 femoral neck fractures: a biomechanical study
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.trdizin0
rdl.citation.wos0
rdl.departmentDepartment of Orthopedics and Traumatology, Elazığ Fethi Sekin City Hospital, Elazığ Türkiye
rdl.departmentDepartment of Machine and Metallic Technology, Munzur University, Tunceli, Türkiye
rdl.departmentDepartment of Orthopedics and Traumatology, Fırat University, Elazığ, Türkiye
rdl.oa.statusgold
rdl.oa.statusgreen
rdl.oa.urlhttps://www.aott.org.tr/index.php/pub/article/download/4106/4058
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)