Sürdürülebilir Kalkınma Amaçları

  • MakaleYalnız künye2020Scopus SJRQ2
    Investigation of the radiation shielding capability of xPbO – (50 - x) BaO – 50 B 2O 3 glass system using Geant4, Fluka, WinXCOM and comparison of data with the experimental data

    Aşkin, A.; Mutuwong, C.; Nutaro, T.; Dal, M.

    In this study, mass attenuation coefficient (μm), transmission fractions (T), effective atomic numbers (Z eff) and half-value layer (HVL) of the xPbO –(50 - x) BaO –50 B 2O 3 (where x=10,20,30,40mol%) glass system have been determined from the Monte Carlo simulations carried out with Geant4 and Fluka simulation toolkits and WinXCOM database software. The calculated results were compared with the experimentally obtained μm values of the selected glass in order to validate the Geant4 model of HPGe detector and Fluka model of NaI(Tl) detectors. T, Z eff and HVL shielding parameters of the studied glass system indicate that increase of PbO content from 10 to 40% results in a better shielding behaviour thanks to the high atomic number of lead.

    AtıfScopus12WoS8OpenAlex12
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2019Scopus SJRQ1
    Investigation ofthe gamma ray shielding parameters of (100-x)[0.5Li2O–0.1B2O3–0.4P2O5]-xTeO2 glasses using Geant4 and FLUKA codes

    Aşkın, A.; Sayyed, M.I.; Sharma, Amandeep; Dal, M.; El-Mallawany, R.; Kaçal, M.R.

    In the present work, the radiation shielding proeprties of lithium borophosphtellurite glass system with the composition of (100-x) [0.5Li2O-0.1B2O3–0.4P2O5]-xTeO2 (x = 0, 10, 20, 30 and 40 mol%) were reported. The mass attenuation coefficient (μ/ρ) of the selected glass system (LiBPTe0, LiBPTe10, LiBPTe20, LiBPTe30 and LiBPTe40) was calculated at 356 keV, 662 keV, 1173 keV and 1330 keV photon energies by using Geant4 and FLUKA codes and the results were compared to the values obtained theoretically using WinXcom software. The correlation theory has been used to calculate the correlation coefficients (R2) between the results from WinXcom and the both simulations codes (Geant4 and FLUKA) for each sample. Moreover, some other radiation shielding parameters such as effective atomic number, photon transmission, mean free path and half value layer were calculated. The gamma photon transmission results showed that the transmission values of the 356 keV photons are lower than those of energies 662, 1173 and 1330 keV. At 356 keV, the transmission value for LiBPTe0 (at 6 cm thickness) is found to be 0.245 while at the same energy and thickness the transmission value is 0.088 for LiBPTe40. Out of all the glasses considered in present work, LiBPTe40 possesses the highest values of effective atomic number (Zeff). The Zeff values for the present glasses are 8.02, 9.55, 11.16, 12.85 and 14.64 for LiBPTe0, LiBPTe10, LiBPTe20, LiBPTe30 and LiBPTe40 respectively at 356 keV. The mass attenuation coefficient and effetive atomic number results showed that utilization 40% mol of TeO2 significantly improves the gamma ray shielding properties of the selected glass system. The shielding effectiveness of the selected samples was compared with other reference materials namely two radiation shielding glasses and four concretes used in different shielding purposes in terms of the mean free path (MFP) at 356 keV. The results revealed that the MFP of RS-253-G18 is lower than LiBPTe0sample. Moreover, the MFP of ordinary concrete is higher than the MFP of all glasses under examination, thus the investigated tellurite glasses have better attenuation features than the ordinary concrete.

    AtıfScopus106OpenAlex107
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2019Scopus SJRQ3
    Assessment of the mass attenuation coefficients of granite, basalt, andesite and tuff stones with the Geant4 model of a high-purity germanium detector

    Aşkin, A.; Dal, M.

    In this work, the radiation shielding properties of various natural stones, such as granite, basalt, andesite and tuff, were determined by using Monte-Carlo simulations performed with the Geant4 model of a high-purity germanium (HPGe) detector. Mass attenuation coefficients were calculated for γ-ray energies of 80.9, 140.5, 356.5, 661.6, 1173.2 and 1332.5 keV and for the sample thicknesses between 1 and 7 cm. The results of this study indicate that the stone samples have lower mass attenuation values varying in the range from - 28.8 % to - 3.7 % compared to lead. Among the measured stone samples, the mass attenuation values of tuff stone are closest to lead (above 661.6 keV).

    AtıfScopus7WoS6OpenAlex8
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2016Scopus SJRQ2
    Storm water retention and actual evapotranspiration performances of experimental green roofs in French oceanic climate

    Yilmaz, D.; Sabre, M.; Lassabatère, L.; Dal, M.; Rodriguez, F.

    Green roofs are promising urban management tools from the standpoint of both rainwater management and microclimatology. They are considered as a storm water mitigation technique and may also favour evapotranspiration fluxes, which can be beneficial for urban comfort during summer periods. In France, however, water retention performance of green roofs remains unknown, and published values are often unsuitable. Six experimental roofs, including two thicknesses of growing media, three types of vegetation cover and bare surfaces, were monitored for two years in Nantes and compared to an experimental gravel flat roof. The thickest media combined with the most densely vegetated cover yields the best results in terms of storm water mitigation and actual evapotranspiration. In winter, the rainwater retention performance is clearly dependent on the type of experimental roof vegetation. This kind of experimental set-up is well suited to assisting urban planners design tools for storm water mitigation in buildings.

    • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
    • SDG 13 · İklim Eylemi
    AtıfWoS22OpenAlex28
    Web of Scienceİncele