Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleYalnız künye2026Scopus SJRQ3Sensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution
Ekşi, Osman; İpek, Yeliz; Koçak, Berna
In this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs.
- MakaleAçık Erişim2026Scopus SJRQ2Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode
Koçak, Berna; İpek, Yeliz
In this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.
- MakaleYalnız künye2026Scopus SJRQ2Synthesis of Aminothiophene derivative complexes and electrochemical sensor application for carbofuran pesticide
Taş, Abdurrahim; İpek, Yeliz; Adiguzel, Ragip
In this study, a ligand named 2-amino-6-ethyl-4,5,6,7-tetrahydrothieno[2,3-c]pyridine-3‑carbonitrile (ATL), which is an aminothiophene ligand, was synthesized. ATL was used to synthesize ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes. The chemical structures of the complexes were elucidated by spectroscopic methods such as FT-IR, UV–visible, and LC-MS analysis, as well as TG-DTA analysis, magnetic susceptibility measurements, and elemental analysis. Finally, the electrochemical characterization of ATL and the electrochemical sensor application of its complexes was performed. In electrochemical sensor studies, a carbofuran pesticide sensor application was investigated. ATL exhibited an irreversible oxidation peak around 1.0 V. It was observed that ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes behaved similarly to ATL and exhibited an irreversible oxidation peak at the same potential. Carbofuran pesticide was added to the sensor medium using the standard addition method. The changes in peak current with different carbofuran concentrations constituted the data of the amperometric sensor application, and the changes in the peak potential constituted the data of the voltammetric sensor application. Linear working ranges, LOD, and LOQ values were calculated for ATL, ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes, separately. The widest operating range as a voltammetric sensor was achieved with the ATL: 20 μmol L−1 to 350 μmol L−1. The lowest LOD and LOQ values were achieved with the ATL-Co(II) complex for voltammetric detection as 8.8 μmol L−1 and 29.2 μmol L−1, respectively. The lowest LOD and LOQ values were achieved with the ATL-Co(II) complex as 1.6 μmol L−1 and 5.2 μmol L−1 with the amperometric technique, respectively.

