Silver/Selenium/Chitosan-doped Hydroxyapatite coatings on biological NiTi alloy: In vitro biodegradation analysis

MakaleYalnız künyeScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Abstract: Nitinol (NiTi) substrates were bioceramic coated by single layer Hydroxyapatite (HA), double layer HA/Silver (Ag) and double-layered HA/Selenium (Se)–Chitosan (Cht) substitutions by sol–gel method. Surface morphologies and adhesion strengths of the obtained coatings were characterized by means of SEM, EDX, XRD, and adhesion tests. Crack-free coatings were obtained in single layer-HA (S1), double layer HA/Ag (S2), and double-layered HA/Selenium–Cht (S3) coatings on NiTi alloys executed via the sol–gel method. Degradation behavior was analyzed in via simulated body fluid (SBF) environment by means of weight loss (%) and ion release rates for 1–4 weeks of immersion periods. The degraded coating particles were measured and metallic ions were detected quantitatively by an inductively coupled plasma–mass spectrometer (ICP–MS). The results show that such coatings could minimize and/or prevent the degradation of metallic ions and weight loss (%) from the coated substrates. From the overall results, HA/Ag double layer biocomposite (S2)-coated NiTi substrates revealed the highest adhesion strength and lowest weight loss and degradation. It was also shown in all groups that the Ni ion release from the NiTi substrates was prevented by the coatings. [Figure not available: see fulltext.].

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3549Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s10971-019-04939-yYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
10
WoS
9
OpenAlex
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSay, Y.
dc.contributor.authorAksakal, B.
dc.date.accessioned2026-10-28T14:56:46.973679718Z
dc.date.available2026-10-28T14:56:46.973679718Z
dc.date.issued2019
dc.description.abstractAbstract: Nitinol (NiTi) substrates were bioceramic coated by single layer Hydroxyapatite (HA), double layer HA/Silver (Ag) and double-layered HA/Selenium (Se)–Chitosan (Cht) substitutions by sol–gel method. Surface morphologies and adhesion strengths of the obtained coatings were characterized by means of SEM, EDX, XRD, and adhesion tests. Crack-free coatings were obtained in single layer-HA (S1), double layer HA/Ag (S2), and double-layered HA/Selenium–Cht (S3) coatings on NiTi alloys executed via the sol–gel method. Degradation behavior was analyzed in via simulated body fluid (SBF) environment by means of weight loss (%) and ion release rates for 1–4 weeks of immersion periods. The degraded coating particles were measured and metallic ions were detected quantitatively by an inductively coupled plasma–mass spectrometer (ICP–MS). The results show that such coatings could minimize and/or prevent the degradation of metallic ions and weight loss (%) from the coated substrates. From the overall results, HA/Ag double layer biocomposite (S2)-coated NiTi substrates revealed the highest adhesion strength and lowest weight loss and degradation. It was also shown in all groups that the Ni ion release from the NiTi substrates was prevented by the coatings. [Figure not available: see fulltext.].
dc.identifier.doi10.1007/s10971-019-04939-y
dc.identifier.eissn1573-4846
dc.identifier.endpage442
dc.identifier.issn0928-0707
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85064956504
dc.identifier.startpage434
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3549
dc.identifier.volume90
dc.identifier.wosWOS:000466161000024
dc.language.isoen
dc.publisherSpringer New York LLC
dc.relation.ispartofJournal of Sol-Gel Science and Technology
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBiodegradation
dc.subjectHydroxyapatite
dc.subjectNiTi
dc.subjectSol–gel coating
dc.subject.classificationMaterials Science, Ceramics
dc.subject.classificationMaterials Science
dc.subject.otherAdhesion
dc.subject.otherBinary alloys
dc.subject.otherBiodegradation
dc.subject.otherBond strength (materials)
dc.subject.otherCoatings
dc.subject.otherHydroxyapatite
dc.subject.otherInductively coupled plasma
dc.subject.otherIons
dc.subject.otherPhotodegradation
dc.subject.otherSilver
dc.subject.otherSilver alloys
dc.subject.otherSols
dc.subject.otherCoated substrates
dc.subject.otherCrack-free coatings
dc.subject.otherDegradation behavior
dc.subject.otherGel coatings
dc.subject.otherHydroxyapatite coating
dc.subject.otherImmersion periods
dc.subject.otherNiTi
dc.subject.otherSimulated body fluids
dc.subject.otherTitanium alloys
dc.titleSilver/Selenium/Chitosan-doped Hydroxyapatite coatings on biological NiTi alloy: In vitro biodegradation analysis
dc.typeArticle
rdl.citation.openalex11
rdl.citation.scopus10
rdl.citation.wos9
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)