Highly sensitive DNA-based electrochemical biosensor for analysis of oseltamivir used in treatment of COVID–19

MakaleYalnız künyeScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Promising clinical results were obtained in the treatment of coronavirus disease by using favipiravir, umifenovir, remdesivir, ribavirin, lopinavir–ritonavir, oseltamivir, etc., antiviral drug active agents. In this study, quantitative analysis of oseltamivir neuraminidase inhibitor was carried out using electrochemical techniques. DNA-based electrochemical biosensors are generally used for analysis of anticancer and antitumor medicines. The present study introduces a novel DNA-based electrochemical sensor for neuraminidase inhibitor drug oseltamivir. The developed sensor enables the analysis of oseltamivir in a more environmentally friendly, more economical and faster way. It can be used in quality control laboratories in tablet production and will provide traceability of the drug in drug development studies and analysis in urine samples. For this purpose, a modified glassy carbon electrode was used as a working electrode. The glassy carbon electrodes alone cannot detect the oseltamivir. Guanine base, which was determined to interact with oseltamivir and found in the deoxyribonucleic acid structure, was used as an electrochemical biosensor agent. The guanine base was immobilized on glassy carbon electrode using glutardialdehyde as a crosslinker material and GA2–Guanine/GCE electrode was achieved. Two working ranges were determined for the Britton-Robinson buffer solution, tablet sample, and urine sample containing oseltamivir. The lowest detection limits (LODs) were calculated as 7.16 × 10−9 mol L−1, 9.05 × 10−9 mol L−1 and 6.19 × 10−6 mol L−1 for Britton-Robinson buffer solution, tablet sample solution, and urine sample solution, respectively. The recovery ratio for the proposed sensor ranged between 86.6 and 103.5%.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1207Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s10800-024-02213-wYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
3
WoS
3
OpenAlex
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKeçeci, Ali
dc.contributor.authorKoçak, Berna
dc.contributor.authorİpek, Yeliz
dc.date.accessioned2026-10-28T14:53:59.543547785Z
dc.date.available2026-10-28T14:53:59.543547785Z
dc.date.issued2025
dc.description.abstractPromising clinical results were obtained in the treatment of coronavirus disease by using favipiravir, umifenovir, remdesivir, ribavirin, lopinavir–ritonavir, oseltamivir, etc., antiviral drug active agents. In this study, quantitative analysis of oseltamivir neuraminidase inhibitor was carried out using electrochemical techniques. DNA-based electrochemical biosensors are generally used for analysis of anticancer and antitumor medicines. The present study introduces a novel DNA-based electrochemical sensor for neuraminidase inhibitor drug oseltamivir. The developed sensor enables the analysis of oseltamivir in a more environmentally friendly, more economical and faster way. It can be used in quality control laboratories in tablet production and will provide traceability of the drug in drug development studies and analysis in urine samples. For this purpose, a modified glassy carbon electrode was used as a working electrode. The glassy carbon electrodes alone cannot detect the oseltamivir. Guanine base, which was determined to interact with oseltamivir and found in the deoxyribonucleic acid structure, was used as an electrochemical biosensor agent. The guanine base was immobilized on glassy carbon electrode using glutardialdehyde as a crosslinker material and GA2–Guanine/GCE electrode was achieved. Two working ranges were determined for the Britton-Robinson buffer solution, tablet sample, and urine sample containing oseltamivir. The lowest detection limits (LODs) were calculated as 7.16 × 10−9 mol L−1, 9.05 × 10−9 mol L−1 and 6.19 × 10−6 mol L−1 for Britton-Robinson buffer solution, tablet sample solution, and urine sample solution, respectively. The recovery ratio for the proposed sensor ranged between 86.6 and 103.5%.
dc.description.sponsorshipMunzur Üniversitesi, MU, (YLMUB022-09)
dc.description.sponsorshipMunzur Üniversitesi, MU
dc.identifier.doi10.1007/s10800-024-02213-w
dc.identifier.eissn1572-8838
dc.identifier.endpage1087
dc.identifier.issn0021-891X
dc.identifier.issue4
dc.identifier.scopus2-s2.0-105001084031
dc.identifier.startpage1073
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1207
dc.identifier.volume55
dc.identifier.wosWOS:001341173900001
dc.language.isoen
dc.publisherSpringer Science and Business Media B.V.
dc.relation.ispartofJournal of Applied Electrochemistry
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCOVID–19
dc.subjectDNA-based biosensor
dc.subjectDrug analysis
dc.subjectNeuraminidase inhibitor
dc.subjectOseltamivir
dc.subject.classificationElectrochemistry
dc.subject.otherControlled drug delivery
dc.subject.otherCoronavirus
dc.subject.otherCOVID-19
dc.subject.otherDisease control
dc.subject.otherElectrochemical biosensors
dc.subject.otherGlass membrane electrodes
dc.subject.otherGlassy carbon
dc.subject.otherBritton-Robinson buffer
dc.subject.otherBuffer solutions
dc.subject.otherDNA-based biosensors
dc.subject.otherDrug analysis
dc.subject.otherElectrochemical biosensor
dc.subject.otherGlassy carbon electrodes
dc.subject.otherGuanine basis
dc.subject.otherNeuraminidase inhibitors
dc.subject.otherOseltamivir
dc.subject.otherUrine sample
dc.subject.otherAntiviral agents
dc.titleHighly sensitive DNA-based electrochemical biosensor for analysis of oseltamivir used in treatment of COVID–19
dc.typeArticle
rdl.citation.openalex3
rdl.citation.scopus3
rdl.citation.wos3
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)