Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

In this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/896Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11696-026-05240-3Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKoçak, Berna
dc.contributor.authorİpek, Yeliz
dc.date.accessioned2026-10-28T14:53:44.079916094Z
dc.date.available2026-10-28T14:53:44.079916094Z
dc.date.issued2026
dc.description.abstractIn this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TUBITAK
dc.identifier.doi10.1007/s11696-026-05240-3
dc.identifier.eissn2585-7290
dc.identifier.issn0366-6352
dc.identifier.scopus2-s2.0-105043675237
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/896
dc.identifier.wosWOS:001810914600001
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofChemical Papers
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectElectrochemical analysis
dc.subjectFe<sub>2</sub>O<sub>3</sub>
dc.subjectGlutardialdehyde
dc.subjectModified electrode
dc.subjectTetracycline
dc.subjectVoltammetry
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationChemistry
dc.subject.otherPOTENTIAL SWEEP VOLTAMMETRY
dc.subject.otherANTIBIOTICS
dc.subject.otherSURFACE
dc.subject.otherSENSOR
dc.titleElectrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statushybrid
rdl.oa.urlhttps://link.springer.com/content/pdf/10.1007/s11696-026-05240-3.pdf
rdl.publication.statusinPress
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)