Sensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution

MakaleYalnız künyeScopus SJRQ3

Özet

In this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/977Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/slct.202507118Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorEkşi, Osman
dc.contributor.authorİpek, Yeliz
dc.contributor.authorKoçak, Berna
dc.date.accessioned2026-10-28T14:53:47.873875208Z
dc.date.available2026-10-28T14:53:47.873875208Z
dc.date.issued2026
dc.description.abstractIn this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs.
dc.description.sponsorshipThe Scientific Research Projects Coordination Unit of Munzur niversitesi [YLMUB023-02']
dc.identifier.articlenumbere07118
dc.identifier.doi10.1002/slct.202507118
dc.identifier.issn2365-6549
dc.identifier.issue15
dc.identifier.scopus2-s2.0-105035842242
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/977
dc.identifier.volume11
dc.identifier.wosWOS:001742789400001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofChemistrySelect
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectboron-doped diamond electrode
dc.subjectchromium(III) oxide
dc.subjectelectrochemical analysis
dc.subjectgentamicin sulfate
dc.subjectmodified electrode
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationChemistry
dc.titleSensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)