Sensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution
Özet
In this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs.
Anahtar Kelimeler
- Scopus
- 0
- WoS
- 0
- OpenAlex
- 0
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Ekşi, Osman | |
| dc.contributor.author | İpek, Yeliz | |
| dc.contributor.author | Koçak, Berna | |
| dc.date.accessioned | 2026-10-28T14:53:47.873875208Z | |
| dc.date.available | 2026-10-28T14:53:47.873875208Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | In this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs. | |
| dc.description.sponsorship | The Scientific Research Projects Coordination Unit of Munzur niversitesi [YLMUB023-02'] | |
| dc.identifier.articlenumber | e07118 | |
| dc.identifier.doi | 10.1002/slct.202507118 | |
| dc.identifier.issn | 2365-6549 | |
| dc.identifier.issue | 15 | |
| dc.identifier.scopus | 2-s2.0-105035842242 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/977 | |
| dc.identifier.volume | 11 | |
| dc.identifier.wos | WOS:001742789400001 | |
| dc.language.iso | en | |
| dc.publisher | John Wiley and Sons Inc | |
| dc.relation.ispartof | ChemistrySelect | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | boron-doped diamond electrode | |
| dc.subject | chromium(III) oxide | |
| dc.subject | electrochemical analysis | |
| dc.subject | gentamicin sulfate | |
| dc.subject | modified electrode | |
| dc.subject.classification | Chemistry, Multidisciplinary | |
| dc.subject.classification | Chemistry | |
| dc.title | Sensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution | |
| dc.type | Article | |
| rdl.citation.openalex | 0 | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.oa.status | closed | |
| rdl.scopus.quartile | Q3 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
