Synthesis and characterization of TiNbZrMo medium-entropy bio-composites: Microstructure, mechanical properties, and in vitro degradation
Özet
This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1–15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5–5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.
Anahtar Kelimeler
- Scopus
- 2
- WoS
- 1
- OpenAlex
- 3
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Say, Yakup | |
| dc.date.accessioned | 2026-10-28T14:55:12.821469089Z | |
| dc.date.available | 2026-10-28T14:55:12.821469089Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1–15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5–5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications. | |
| dc.identifier.articlenumber | e35415 | |
| dc.identifier.doi | 10.1002/jbm.b.35415 | |
| dc.identifier.eissn | 1552-4981 | |
| dc.identifier.issn | 1552-4973 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pmid | 38773744 | |
| dc.identifier.scopus | 2-s2.0-85193856475 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/2304 | |
| dc.identifier.volume | 112 | |
| dc.identifier.wos | WOS:001228315900001 | |
| dc.language.iso | en | |
| dc.publisher | John Wiley and Sons Inc | |
| dc.relation.ispartof | Journal of Biomedical Materials Research - Part B Applied Biomaterials | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | bio-composite | |
| dc.subject | hydroxyapatite | |
| dc.subject | medium entropy alloys | |
| dc.subject | TiNbZrMo | |
| dc.subject.classification | Engineering, Biomedical | |
| dc.subject.classification | Materials Science, Biomaterials | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Materials Science | |
| dc.subject.other | Alloys | |
| dc.subject.other | Biocompatible Materials | |
| dc.subject.other | Durapatite | |
| dc.subject.other | Entropy | |
| dc.subject.other | Materials Testing | |
| dc.subject.other | Niobium | |
| dc.subject.other | Titanium | |
| dc.subject.other | Zirconium | |
| dc.subject.other | Bearings (machine parts) | |
| dc.subject.other | Biodegradation | |
| dc.subject.other | Compression testing | |
| dc.subject.other | Compressive strength | |
| dc.subject.other | Elastic moduli | |
| dc.subject.other | Fourier transform infrared spectroscopy | |
| dc.subject.other | High-entropy alloys | |
| dc.subject.other | Hydroxyapatite | |
| dc.subject.other | Mechanical alloying | |
| dc.subject.other | Microstructure | |
| dc.subject.other | Molybdenum alloys | |
| dc.subject.other | Niobium alloys | |
| dc.subject.other | Scanning electron microscopy | |
| dc.subject.other | Tensile strength | |
| dc.subject.other | Titanium alloys | |
| dc.subject.other | X ray diffraction | |
| dc.subject.other | Zircaloy | |
| dc.subject.other | molybdenum | |
| dc.subject.other | nickel | |
| dc.subject.other | alloy | |
| dc.subject.other | biomaterial | |
| dc.subject.other | Bio-media | |
| dc.subject.other | Biocomposite | |
| dc.subject.other | In-vitro | |
| dc.subject.other | Load-bearing | |
| dc.subject.other | Mechanical | |
| dc.subject.other | Medium entropy | |
| dc.subject.other | Medium entropy alloy | |
| dc.subject.other | Synthesis and characterizations | |
| dc.subject.other | Tinbzrmo | |
| dc.subject.other | X ray diffractometers | |
| dc.subject.other | Article | |
| dc.subject.other | degradation | |
| dc.subject.other | energy dispersive X ray spectroscopy | |
| dc.subject.other | hardness | |
| dc.subject.other | in vitro study | |
| dc.subject.other | mechanical test | |
| dc.subject.other | metallurgy | |
| dc.subject.other | particle size | |
| dc.subject.other | surface property | |
| dc.subject.other | Vickers hardness | |
| dc.subject.other | Young modulus | |
| dc.subject.other | chemistry | |
| dc.subject.other | Reinforcement | |
| dc.title | Synthesis and characterization of TiNbZrMo medium-entropy bio-composites: Microstructure, mechanical properties, and in vitro degradation | |
| dc.type | Article | |
| rdl.citation.openalex | 3 | |
| rdl.citation.scopus | 2 | |
| rdl.citation.wos | 1 | |
| rdl.department | Department of Machine and Metallic Technology, Munzur University, Tunceli, Turkey | |
| rdl.oa.status | closed | |
| rdl.scopus.quartile | Q2 | |
| rdl.sdg | SDG03 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |