Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleYalnız künye2026Scopus SJRQ3The relationship between muscle strength and oxygenation and activities of daily living in adolescents and young adults with pulmonary arterial hypertension
Dik, Jan; Topcuoglu, Ceyhun; Vardar-Yagli, Naciye; Goksuluk, Merve Basol; Aypar, Ebru; Alehan, Dursun; Saglam, Melda
Pulmonary arterial hypertension leads to dyspnoea, fatigue, and oxygen desaturation, limiting activities of daily living and functional capacity. This study aimed to evaluate the impact of pulmonary arterial hypertension on activities of daily living performance, functional capacity, peripheral muscle strength, oxygen dynamics, and energy expenditure. Eighteen adolescents and young adults with pulmonary arterial hypertension (10 females, 8 males; age 9–30 years) and 15 healthy controls (10 males, 5 females; age 9–30 years) were included. Peripheral muscle strength was assessed using a handheld dynamometer, functional capacity via the 6-minute walk test, and muscle oxygenation through near-infrared spectroscopy. Lower-limb endurance was evaluated with the 1-minute sit-to-stand test and activities of daily living performance with the Glittre Activities of Daily Living test. Compared to controls, the pulmonary arterial hypertension group had significantly lower 6-minute walk test distance (441.9 m versus 636.9 m; p < 0.001), reduced sit-to-stand repetitions (28 versus 42.1; p < 0.001), weaker peripheral strength, and lower minimum muscle oxygen saturation (24.9% versus 51.8%; p < 0.001). Glittre Activities of Daily Living test duration was longer (143 s versus 105 s; p < 0.001), with greater oxygen desaturation (−13% versus −1%; p < 0.001), higher dyspnoea scores using modified Borg scale (5 versus 1; p < 0.001), and blunted heart rate response (ΔHR [change in heart rate]: 32 versus 64; p = 0.011). These findings demonstrate that pulmonary arterial hypertension significantly impairs both cardiopulmonary and peripheral muscle function. Protecting muscle health and improving functional capacity should be prioritised to enhance quality of life in this population.
- MakaleYalnız künye2025Scopus SJRQ1New testimony for local elites in Sophene during the Hellenistic period: Rabat Fortress and its Middle Aramaic inscription in a rocky landscape
Danışmaz, Harun; Adalı, Selim Ferruh; Şahin, Özgür
This study is concerned with the evaluation of a recently discovered Aramaic inscription and other archaeological remains found at Rabat Fortress (in Tunceli, Türkiye). The Hellenistic period Aramaic funerary text was composed in memory of a local lord from Sophene’s local political elite, with connections to the Orontid dynasty. This is the first known local Aramaic inscription from Sophene. The Aramaic inscription introduced in this study provides significant new information about the Hellenistic-period context for rock-cut stepped tunnels and single-roomed rock-cut tombs known across eastern Anatolia. The Rabat Fortress site provides corroborating evidence for the dating of the stepped tunnels that exhibit the same rock-cutting techniques in the same region to the Hellenistic and later periods in the rocky landscape. The inscription is rendered in a unique Sophene adaptation of the Middle Aramaic script extant on a corner block inside the Fortress. Its funerary context in rocky landscape and the inscription’s script and content indicate that the local elite at Rabat Fortress used Aramaic, and the notion of Orontid lineage to connect with the kingdom of Sophene’s central authority, which positioned itself between Hellenistic and Iranian traditions.
- MakaleAçık Erişim2019Scopus SJRQ2Frictionless Contact Problem for a Functionally Graded Layer Loaded Through Two Rigid Punches Using Finite Element Method
Polat, A.; Kaya, Y.; Bendine, K.; Özşahin, T.Ş.
In this study, continuous contact problem in the functionally graded (FG) layer loaded with two rigid flat blocks resting on the elastic semi-infinite plane was analyzed by the finite element method. The two-dimensional numerical model of the FG layer was made with the software added to the ANSYS program. This software can be adapted to all contact problem types by making minor changes. The accuracy check of the program was performed by comparing with the analytical solution of the problem by homogeneous layer and its solution by the finite element method. So, fast and practical solutions can be obtained by the developed finite element method on many applications such as; automotive, aviation and space industry applications. The comparisons made showed that the proposed solution gave good results at acceptable levels. In the problem, it was thought that all surfaces were frictionless. The external loads P and Q were transmitted to the FG layer via two flat rigid blocks. Normal stresses between the FG layer and the elastic plane, initial separation loads, initial separation distances and contact stresses under the blocks were investigated for various dimensionless quantities.
AtıfScopus14WoS14OpenAlex11İncele
- Kitap BölümüYalnız künye2019Masculine dreams: Henry V and the Jacobean politics of court performance
Öğütcü, Murat
AtıfScopus7OpenAlex3İncele
- DergiJournal of Mechanics
- DergiAnatolian Studies
- DergiCardiology in the Young

