Sürdürülebilir Kalkınma Amaçları
Yazarlar
- Dikici, B.(2)
- Niinomi, M.(2)
- Yilmazer, H.(2)
- Aksakal, B.(1)
- Ali, L.A.(1)
- Aslan, N.(1)
- Dikici, Burak(1)
- Guler, Omer(1)
- Nakai, M.(1)
- Niinomi, Mitsuo(1)
- Ozkul, Iskender(1)
- Say, Y.(1)
- Say, Yakup(1)
- Sen, A.(1)
- Topuz, M.(1)
- Yilmazer, Y.(1)
Yayınlar
- MakaleYalnız künye2024Scopus SJRQ2Recycling Ti1.0Nb0.3Ta0.07Zr0.05 Conventional Alloys: Production of Non-equimolar TiZrCrNb0.3Ta0.07 Medium Entropy Alloys with the Addition of Cr for Improved In Vitro Corrosion Resistance
Guler, Omer; Say, Yakup; Dikici, Burak; Ozkul, Iskender; Niinomi, Mitsuo
A non-equimolar TiZrCrNb0.3Ta0.07 medium entropy alloy (MEA) was successfully designed as theoretical and produced by arc-melting method from Ti1.0Nb0.3Ta0.07Zr0.05 (TNTZ) scraps for possible usage in biomedical applications in this study. The main aim of this study is to find an alternative way to recycle with a reduced carbon footprint the available TNTZ conventional alloy and convert it to a value-added product during this recycling such as medium entropy alloys (MEAs) via using less energy. To examine the microstructural changes induced by the annealing process, scanning electron microscopy was employed. The chemical composition of the HEAs was assessed using energy-dispersive spectroscopy and x-ray photoelectron spectroscopy. Additionally, x-ray diffraction analysis was used to determine the crystallographic structure and phase composition of HEAs. Furthermore, in order to evaluate the electrochemical corrosion performance of the alloys, comprehensive in vitro corrosion tests were conducted in a simulated body fluid solution, specifically Hanks's Balanced Salt Solution. Some elemental segregation has been observed after the annealing process. A big migration of Zr and Cr elements was observed in the samples from the interdendritic region to the dendritic area during the annealing process. This segregation resulted in approximately 1.4 times increase in the hardness of the MEA. The electrochemical corrosion results showed that the in vitro resistance of the MEAs was higher than that of its conventional scraps.
AtıfScopus5OpenAlex5İncele
- MakaleYalnız künye2023Scopus SJRQ1In-vitro corrosion and surface properties of PVD-coated β-type TNTZ alloys for potential usage as biomaterials: Investigating the hardness, adhesion, and antibacterial properties of TiN, ZrN, and CrN film
Ali, L.A.; Dikici, B.; Aslan, N.; Yilmazer, Y.; Sen, A.; Yilmazer, H.; Niinomi, M.
In this study, the corrosion and surface properties of non-toxic and non-allergenic β-type Ti–29Nb–13Ta–4.6Zr alloys (TNTZ) coated with TiN, ZrN, and CrN layers using the PVD technique were investigated under in-vitro conditions. The coatings' hardness, adhesion resistance, and antibacterial properties were also studied, with a focus on their potential usage as biomaterials. The corrosion tests were conducted using potentiodynamic polarization, the hardness tests were conducted using the Knoop method, and the adhesion tests were conducted using pull-off tests. The wetting properties of the coatings were examined through contact angle and 3D morphological analysis. The coatings were characterized using SEM-EDS and XRD. The results showed that the adhesion resistance of all coatings was significantly higher than the expected adhesion strength for biomaterial coatings, while their corrosion resistance was higher compared to the uncoated alloy. Besides, the study demonstrates the potential of TiN, ZrN, and CrN coatings on β-type TNTZ for use as a biomaterial with desirable surface and antibacterial properties.
AtıfScopus29OpenAlex27İncele
- MakaleYalnız künye2018Scopus SJRQ3Synthesis and Characterization of Hydroxyapatite/TiO2 Coatings on the β-Type Titanium Alloys with Different Sintering Parameters using Sol-Gel Method
Dikici, B.; Niinomi, M.; Topuz, M.; Say, Y.; Aksakal, B.; Yilmazer, H.; Nakai, M.
In this study, hydroxyapatite (HA) based composite films were successfully syntheses on the β-type Ti29Nb13Ta4.6Zr (TNTZ). The solutionized TNTZ substrates coated with HA and HA/Titania (TiO2) bioactive composite coatings by sol-gel method under various sintering parameters related to sintering temperatures and heating ramp rates. Microstructural observations of the coatings revealed that apatite was formed on the substrates. The hardness values of the coatings increase with increasing both the sintering temperature and the TiO2 concentration in the coatings layer. However, it was found that the heating ramp rate of the sintering was not affecting the hardness values so much. Also, the hardness values of the HA/TiO2 composite coatings at all sintering temperatures were higher than only HA coated TNTZ samples due to the existence TiO2 phases in the HA matrix. Results indicating that the doping of HA with TiO2, improve the physical consistency between the coating layer and the substrates and provide a better inter-particle bonding due to the existence TiO2 phases in the HA.
AtıfScopus42OpenAlex43İncele