Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleYalnız künye2026Scopus SJRQ2
    Influence of Boron Addition on the Microstructure, Mechanical, and Corrosion Behavior of NiCrBSi Alloys Prepared by Spark Plasma Sintering

    Çelik, Ertuğrul

    This study investigates the effect of boron addition on the microstructural, mechanical, and corrosion properties of NiCrBSi alloy fabricated by the spark plasma sintering (SPS) method. Boron was added at levels of 1.5, 3, and 4.5 wt.%, and sintering was conducted at 950 °C for 5 min. Microstructural characterization was carried out using SEM–EDS and XRD analyses, hardness was measured by the Vickers method, and densities were determined according to Archimedes’ principle. The transverse rupture strength (TRS) was obtained by three-point bending tests, while wear performance was evaluated in a reciprocating wear mode. Corrosion behavior was examined through potentiodynamic polarization in a 0.1 M HCl solution. Increasing boron content promoted the formation of nickel and chromium boride phases, enhancing hardness (up to 675 HV0.5) and wear resistance but reducing TRS values due to brittle intermetallic formation. Furthermore, corrosion protection efficiency improved, reaching about 65.9% at 4.5 wt.% B addition.

  • MakaleYalnız künye2026Scopus SJRQ2
    Oxide Dispersion, Microstructure, and Functional Evolution in La2O3 Modified Cu-Al-Mn-Fe Shape Memory Alloys

    Karaduman, Oktay; Doğan, Fatih; Dehghanpour, Heydar; Yüzüak, Gizem Durak; Yüzüak, Ercüment; Canbay, Canan Aksu

    Cu-Al-Mn-Fe high-temperature shape memory alloys containing 0-1.0 wt.% La2O3 were fabricated by vacuum arc remelting to investigate oxide-dispersion effects on microstructure, martensitic transformation, wear, and corrosion behavior. XRD and SEM analyses revealed that low La2O3 additions (0.2-0.4 wt.%) promoted β1′ martensite refinement and enhanced crystallinity, while higher contents induced structural heterogeneity. The alloy with 0.4 wt.% La2O3 exhibited the highest transformation enthalpy (7.49 J g−1), reduced friction coefficient (~0.55), and the narrowest wear scar (~501 µm). Electrochemical tests in 3.5 wt.% NaCl showed a fivefold decrease in corrosion current density and increased charge-transfer resistance (2512 Ω cm2) for the same composition. Excessive La2O3 led to performance degradation due to particle agglomeration and interfacial defects. The results demonstrated that controlled La2O3 addition enabled microstructural refinement and multifunctional performance enhancement in Cu-based shape memory alloys.

  • MakaleAçık Erişim2026Scopus SJRQ2
    Corrosion behavior and constant load scratch adhesion properties of CeO2 doped ceramic composite layer via micro arc oxidation on Al 1050 alloy

    Ayday, Aysun; Durmaz, Mustafa; Duru, Erhan; Kırsever, Derya; Doğan, Fatih

    In this study, CeO2-doped ceramic coatings were produced on Al 1050 alloy by micro-arc oxidation (MAO) using a silicate-alkaline electrolyte containing 0, 0.5, 1, and 2% CeO2. The aim was to investigate the effect of CeO2 addition on the microstructure, phase composition, corrosion behavior, and constant-load scratch adhesion performance of the coatings. Surface characterization was carried out by SEM, EDS, XRD, and 3D profilometry, while corrosion performance was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy in 3.5 wt% NaCl solution. Scratch tests were also performed to assess the mechanical integrity of the coatings. The results showed that increasing CeO2 content improved coating uniformity, reduced surface roughness and porosity, and promoted the formation of a denser oxide structure. XRD analysis confirmed that γ-Al2O3 was the predominant alumina phase in all coatings, while Ce-containing species were incorporated into the oxide layer without forming additional detectable phases. Electrochemical results revealed that CeO2 addition significantly improved corrosion resistance by lowering the corrosion current density and increasing the polarization resistance. Scratch test results further showed improved adhesion-related behavior with reduced crack formation and surface damage. Overall, CeO2 addition effectively enhanced both the corrosion protection and mechanical performance of MAO coatings on Al 1050 alloy.

    AtıfScopus1OpenAlex1
    Scopusİncele
  • MakaleAçık Erişim2025Scopus SJRQ2
    Effects of ZrN and DLC coatings on morphostructural, corrosion, cell viability, and antibacterial properties of Ti6Al4V scaffolds

    Aslan, Naim; Aksakal, Bünyamin; Cihangir, Salih; Fidan, Ferzan; Yilmazer, Yasemin

    Lightweight and functional metallic materials are consistently favored and attract significant attention in the biomedical field. This study investigates the influence of ZrN and DLC coatings on Ti6Al4V scaffolds with varying porosities (40%, 50%, 60%) for biomedical applications. PVD-deposited coatings exhibited distinct growth mechanisms: High-resolution SEM-FIB analyses revealed columnar ZrN structures due to limited adatom mobility, while DLC formed conformal, amorphous layers via high-energy carbon species. Corrosion resistance decreased in 40% porous DLC and 60% porous ZrN-coated samples, likely due to coating defects and increased electrolyte access through open pores. ZrN coatings showed superior antibacterial activity and attributed to surface reactivity and potential ion release. In contrast, the uncoated 60% porous scaffolds demonstrated highest cell viability, suggesting that excessive coating on highly porous structures may hinder cell–material interactions. Furthermore, the cytotoxicity evaluations indicated that uncoated scaffolds exhibited the highest cell viability (77.51%) at 60% porosity after 48 hours, with ZrN coatings demonstrating better efficacy compared to DLC in the 50% and 60% porosity groups.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus3WoS3OpenAlex3
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2025Scopus SJRQ2
    A Novel CuAlMnFe/CeO2 Composite Alloy: Investigating the Wear and Corrosion Features

    Doğan, Fatih; Duru, Erhan

    Shape memory alloys (SMAs) are known for their exceptional mechanical properties, particularly their superior wear resistance compared to conventional alloys with similar surface hardness. Rare earth oxides are often used as additives to further improve these characteristics. This study investigates the effects of different CeO2 (cerium dioxide) concentrations (0.01 wt.%, 0.1 wt.%, 0.5 wt.%, and 1.0 wt.%) on the properties of CuAlMnFe alloys produced via powder metallurgy (PM). Various analyses were performed, including scanning electron microscopy (SEM), Energy Dispersive Spectroscopy (EDS), X-ray diffraction (XRD), as well as hardness, wear, and corrosion tests. The increase in wear rate is closely related to the formation of precipitates from CeO2 addition. Improvements in wear resistance and hardness are attributed to the effects of grain refinement and solid solution strengthening due to CeO2. Specifically, the wear rate increased from 1.5 × 10−3 mm3/(Nm) to 3.4 × 10−3 mm3/(Nm) with higher CeO2 content. Additionally, the friction coefficient of the CuAlMnFe alloy was reduced with CeO2 addition, indicating enhanced frictional properties. The optimal CeO2 concentration of 0.5% was found to improve grain uniformity, resulting in better wear resistance. Incorporating CeO2 particles into CuAlMnFe alloy enhances hardness and reduces wear rate when used in appropriate amounts. Additionally, it exhibits superior corrosion resistance, as evidenced by a positive shift in corrosion potential in Tafel measurements in solutions and a decrease in corrosion current density. The C0.5 specimen showed the highest corrosion potential (Ecorr, −588 V) and the lowest corrosion current density (icorr, 6.17 μA/cm2) during electrochemical corrosion in 3.5 wt.% NaCl solution.

    AtıfScopus2WoS2OpenAlex2
    ScopusWeb of Scienceİncele
  • MakaleYayıncıda açık erişim2024Scopus SJRQ2
    Selenium Inhibitor Coating on NiTi Shape Memory Alloys by Using Thermal Evaporation System

    Kök, Mediha; Kanca, Muhammed Sait; Say, Yakup; Saydam, Sinan; Dağdelen, Fethi; Qader, Ibrahim Nazem

    NiTi-based memory alloys are often used as intracorporeal implant materials because of their superelasticity and shape memory properties. However, over time, the release of nickel from the NiTi alloy into the body becomes unfavorable; therefore, studies should be conducted to reduce the negative impact of nickel leakage. In this study, the biocompatible selenium element was used to coat NiTi alloys with different thicknesses. The coating process was performed using the thermal evaporation technique. Scanning electron microscopy-Energy Dispersive X-ray Analysis measurements revealed that the surfaces of the samples were well covered. Also, the atomic force microscope device determined the surface roughness of the alloys. The roughness of the surface increased after the coating process. The Tafel test was accomplished to determine the biocompatibility of the coated and uncoated alloys in an artificial body fluid. The corrosion test reveals that Se-coated NiTi alloys have high corrosion resistance.

  • MakaleYalnız künye2024Scopus SJRQ2
    Recycling Ti1.0Nb0.3Ta0.07Zr0.05 Conventional Alloys: Production of Non-equimolar TiZrCrNb0.3Ta0.07 Medium Entropy Alloys with the Addition of Cr for Improved In Vitro Corrosion Resistance

    Guler, Omer; Say, Yakup; Dikici, Burak; Ozkul, Iskender; Niinomi, Mitsuo

    A non-equimolar TiZrCrNb0.3Ta0.07 medium entropy alloy (MEA) was successfully designed as theoretical and produced by arc-melting method from Ti1.0Nb0.3Ta0.07Zr0.05 (TNTZ) scraps for possible usage in biomedical applications in this study. The main aim of this study is to find an alternative way to recycle with a reduced carbon footprint the available TNTZ conventional alloy and convert it to a value-added product during this recycling such as medium entropy alloys (MEAs) via using less energy. To examine the microstructural changes induced by the annealing process, scanning electron microscopy was employed. The chemical composition of the HEAs was assessed using energy-dispersive spectroscopy and x-ray photoelectron spectroscopy. Additionally, x-ray diffraction analysis was used to determine the crystallographic structure and phase composition of HEAs. Furthermore, in order to evaluate the electrochemical corrosion performance of the alloys, comprehensive in vitro corrosion tests were conducted in a simulated body fluid solution, specifically Hanks's Balanced Salt Solution. Some elemental segregation has been observed after the annealing process. A big migration of Zr and Cr elements was observed in the samples from the interdendritic region to the dendritic area during the annealing process. This segregation resulted in approximately 1.4 times increase in the hardness of the MEA. The electrochemical corrosion results showed that the in vitro resistance of the MEAs was higher than that of its conventional scraps.

    • SDG 12 · Sorumlu Üretim ve Tüketim
    AtıfScopus5OpenAlex5
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2024Scopus SJRQ2
    CeO2/SWCNT nanocomposite coating: A novel approach for corrosion application

    Doğan, Fatih

    The coatings were prepared by blending different concentrations of SWCNTs and CeO2 particles with an epoxy resin by hydrothermal method, which was then applied to the substrate through the doctor blade technique. The mixtures were transferred into a 1-L capacity autoclave with a teflon-lined flange type and subjected to hydrothermal treatment at 100°C for 3 h. The surface coatings were applied using a doctor blade. Subsequently, the coated materials were placed in an oven and dried for 12 h at 50°C under vacuum conditions. The samples' structural analysis was examined through x-ray diffraction (XRD). XRD analysis verified the CeO2/SWCNT composite coating, and Fourier transform infrared spectroscopy (FTIR) was utilized to assess the presence of functional groups. Thermodynamic properties and thermal stability of composite coatings that were modified with SWCNTs and CeO2 particles were studied by thermogravimetric analysis (TGA). The impact of the CeO2/SWCNT composite on the anticorrosion capabilities of the epoxy coating was examined through electrochemical impedance spectroscopy (EIS), Nyquist curve, and Tafel slope characterization. Corrosion tests were conducted on the CeO2/SWCNT composite coatings in a 3.5 wt% sodium chloride (NaCl) solution at 25°C to improve corrosion resistance. The concentration of 0.4 wt% CeO2 was found to be optimal for achieving effective corrosion resistance. The composite coating CNT0.6-C0.4 exhibited significantly higher Ecorr (−426 V) and lower Icorr (2.96 × 10−6 A cm−2) values compared to samples from the CNT0, CNT0.2, and CNT0.6 groups. The paper presents a viable solution with CeO2/SWCNT composite coating for the engineering application of corrosive-inhibiting coatings.

    AtıfScopus1WoS1
    ScopusWeb of Scienceİncele
  • MakaleYayıncıda açık erişim2024Scopus SJRQ1
    Investigation of in-vitro bioactivity, electrochemical corrosion, wettability and adhesion properties of bioglass-based coatings modified with Y2O3 and Zr on novel β-type Ti-30Zr-5Mo alloys

    Dikici, B.; Say, Y.; Zhao, X.; Niinomi, M.; Szechyńska-Hebda, M.

    In this study, the in-vitro bioactivity, electrochemical corrosion resistance, wettability, and adhesion properties of bioglass-based coatings modified with Y2O3 and ZrO2 on Ti-30Zr-5Mo alloy were investigated. The coatings were prepared using the sol-gel method and applied to the alloy substrates through dip-coating. The surface morphology and elemental composition of the coatings were analyzed using SEM/EDS and XRD techniques. Potentiodynamic polarization (PDS) and electrochemical impedance spectroscopy (EIS) were employed to assess the electrochemical behavior of the coatings under in-vitro conditions. Contact angle measurements were conducted to evaluate the wettability of the surfaces. Adhesion strength was measured using tensile testing in accordance with ISO 13779-2 standards. Bioactivity tests were performed by immersing the samples in simulated body fluid (SBF). The results demonstrate that the addition of Y2O3 and ZrO2 improves adhesion strength and corrosion potential, but introducing localized galvanic effects that increase the corrosion current density. Besides, the coatings maintained their structural integrity after the bioactivity tests, and promoted new apatite formation.

    AtıfScopus9
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2024Scopus SJRQ2
    The influence of cold rolling and hydroxyapatite coating on the mechanostructure, corrosion resistance, cell viability, and antibacterial activity of ZnCu biodegradable implants

    Aksakal, B.; Karadogan, S.A.; Aslan, N.; Fidan, F.; Yilmazer, Y.; Sezek, S.

    Zinc (Zn) and its alloys exhibit great potential for utilization in biodegradable bone implants. Zn-1Cu biodegradable alloy was produced and were cold rolled at two different deformation rates of 47 and 61%. The samples have been bioceramic coated with the sol–gel method and microstructure-mechanical property changes, corrosion behavior and biocompatibility of the samples were investigated. They were characterized by Optical, SEM, XRD and wettability analysis. The rolled samples showed a significant increase in hardness when compared to the non-rolled samples. The unrolled and 47% rolled samples showed better corrosion resistance compared to 61% rolled samples. Antibacterial effects of the base and sol–gel-coated groups showed higher cell viability ratios than the uncoated groups. Cell viability increased significantly in 47% of the rolled samples after 24, 48, and 72 h, however decreased by up to 70% in 61% of the rolled samples. Graphical abstract: (Figure presented.).

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus2WoS2OpenAlex2
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2024Scopus SJRQ2
    Production of CoCrFeNi(Al/Ti) High-Entropy Alloys by Mechanical Alloying: Optimization of Milling Time and Comparison of Corrosion Susceptibilities

    Say, Yakup; Dikici, Burak; Kaseem, Mosab; Özkul, İskender; Güler, Ömer

    CoCrFeNi alloy is the most well-known four-component equiatomic alloy. In addition, it has a low-cost composition among HEAs. Four-component alloys are considered semi-HEAs. Therefore, a five-component HEA design was made by adding another metal to the main composition of CoCrFeNi. As the fifth metal, two metals such as Al and Ti, which are relatively low in cost and have the potential to improve properties, were chosen. For this purpose, in this study, the effect of Al and Ti on CoCrFeNi main alloy was investigated by producing three different samples as CoCrFeNi, CoCrFeNiAl, and CoCrFeNiTi. The alloys with three different compositions (used three different samples) were successfully produced by the mechanical alloying method. Although Al and Ti have the possibility of intermetallic with other metals in the alloy, such a formation was not observed during mechanical alloying, and it was observed that all metals were homogeneously distributed in the alloy. The microhardness results indicated that CoCrFeNiAl and CoCrFeNiTi samples had similar hardness values. While the hardness of the CoCrFeNi sample was 136 HV, the hardness of the CoCrFeNiAl sample was 262 HV. However, the hardness of the CoCrFeNiTi sample decreased significantly. The hardness of the CoCrFeNiTi sample was measured as 269 HV. It was observed that the addition of Ti and Al to the base alloy was increased a significant change in hardness. It has been observed that Ti supplementation has a more positive effect on improving corrosion properties. It is seen that the corrosion potentials shift toward more negative potentials with the addition of Al and Ti to the CoCrFeNi (−194 mV) alloy (−306 and −224 mV for CoCrFeNiAl and CoCrFeNiTi, respectively). When the surface morphologies of the alloys are compared after corrosion; the damage to the alloy surfaces increases due to the negative Ecorr value in CoCrFeNiAl and CoCrFeNiTi alloys compared to the master alloy. However, the high corrosion current density (12.69 µA/cm2) in the CoCrFeNiTi sample caused much more damage to this alloy. Graphical Abstract: (Figure presented.)

    AtıfScopus14OpenAlex16
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2024Scopus SJRQ1
    Influence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys

    Aksakal, B.; Isın, Ege; Aslan, N.; Cihangir, S.; Sezek, S.; Yilmazer, Yasemin

    Zinc (Zn)-based biodegradable alloys have been at the forefront of absorbable biomaterial research in recent years due to their high biocompatibility and corrosion rates. The arc melting process was used to produce the Zn–1Cu–1Ag biodegradable alloy. The influence of different plastic deformation rates on the microstructure of the material was examined after the cold rolling at deformation rates of 47% and 61%. The undeformed and deformed alloys have been hydroxyapatite-coated using the electrophoretic deposition process to improve its surface, corrosion, and bioactivity properties. Optical, XRD, SEM, and EDS examinations were used to analyze the samples’ uncoated, coated, and rolled-unrolled forms. The nucleation of the (Ag, Cu)Zn4 secondary phase was formed during the rolling process. Hardness and compression tests were used to determine the mechanical properties of cast and rolled alloys, and in vitro corrosion tests were carried out in simulated body fluid. Antimicrobial and cell viability tests are executed to demonstrate the biocompatibility of the deformed and HA-coated Zn–1Cu–1Ag alloy. The mechanical properties were improved after the rolling process, with the highest results found in 47% of the rolled samples exhibiting a compressive strength of 412.65 ± 0.5 MPa and 61% of the rolled samples exhibiting a hardness value of 88.1 ± 0.5 HV. The samples that were rolled (61%) and coated with hydroxyapatite (HA) exhibited the highest level of corrosion resistance. The antimicrobial tests revealed that the rolled and HA coated Zn1Cu1Ag groups exhibited greater inhibition rates (47 and 61%) compared to the other groups when tested against E. coli. The HA-coated groups exhibited good cell viability ratios, with the maximum viability seen in the rolled and HA-coated group at 47%.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus4WoS5OpenAlex4
    ScopusWeb of Scienceİncele
  • BildiriYalnız künye2023
    Investigation of corrosion behavior of ZrN-based PVD coatings on Ti-29Nb-13Ta-4.6Zr alloy in Hank's solution

    Ali, Leila Ait; Aslan, Naim; Yilmazer, Hakan; Niinomi, Mitsuo; Sen, Anil; Dikici, Burak; Benhala, B.; Raihani, A.; Mansouri, K.; Qbadou, M.

    In this study, the TiNbTaZr (TNTZ) alloys, which do not contain toxic and allergic elements, have been coated with hard ZrN physical vapor deposition (PVD) coatings to increase their in-vitro corrosion resistance. In-vitro electrochemical behavior of the ZrN coating and uncoated TNTZ alloy was evaluated using open circuit potential (OCP) and potentiodynamic polarization (PDS) techniques, respectively. The characterizations of the coatings were carried out using scanning electron microscopy (SEM), energy dispersion spectroscopy (EDS), and X-ray diffraction (XRD). The SEM examinations showed that ZrN coating is homogeneous. Besides, ZrN coating had a higher corrosion resistance than uncoated TNTZ alloy in Hank's solution.

  • MakaleAçık Erişim2023Scopus SJRQ2
    Silver and Copper Coating Effects on Surface Morphology, Crystal Structure and Corrosion Behavior of NiTinol Shape Memory Alloy Plate

    Say, Yakup; Kanca, Muhammed Sait; Kök, Mediha

    NiTinol alloy has recently been in high demand in biomaterials applications due to its excellent superelasticity and shape memory properties. This demand has increased the studies on improving the negative properties of the NiTinol alloy, even if it is less. In this study, it was aimed to coat the nickel element in the NiTi alloy with biocompatible elements in order to prevent it from secreting its toxic effect after its implantation into the body. In accordance with this purpose, NiTi shape memory alloys were coated with silver and copper element by using thermal evaporation system, and the surface morphology of the alloys after coating was investigated by SEM–EDX (Scanning Electron microscope), and AFM (Atomic force Microscope). After the measurements, it was observed that the coating was successful and homogeneously distributed on the entire surface of the alloy. In addition, an important and positive result was that, the roughness value of the NiTi alloy was decreased with the coating. The change in the crystal structure of the uncoated and coated NiTi alloy was evaluated using an X-ray device, and it was observed that the silver and copper element peaks were formed along with the B2 phase, which is the main phase of the NiTi alloy. In order to examine the effect of coating on the biocompatibility of NiTi alloy, electrochemical test was performed by rapid measurement method in simulated body fluid and corrosion behavior was investigated. According to these experiments, it was concluded that silver plating is more successful in term of biocompatibility than copper coating.

    AtıfScopus4WoS3OpenAlex4
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2023Scopus SJRQ2
    Replacement of Cu with One-Step Production of CuAg (Ag0.04Cu3.96): Superior Conductivity, Corrosion Resistance, and Hardness

    Cihangir, Salih

    Copper is the forefront of the fundamental metals used in various industries. It is utilized as bulk or electrodeposited on PCBs or interconnects. However, poor corrosion resistance and hardness reduce copper performance and limit its applicability in the fields that require mechanical strength, such as probing applications. Facile electrochemical deposition of Cu(Ag) films was examined in a deep eutectic solvent known for its green nature. SEM–EDS technique was applied for morphostructural and crsytal plane analysis. XRD analysis revealed Cu3.96Ag0.04 phase, and 2% Ag was identified in the Cu(Ag) film in EDS. Four-prope point resistivity analysis was performed via galvano-impedance spectroscopy. Obtained resistivity value of 5 µm thick Cu(Ag) coating was lower than the compliance limit of International Technology Roadmap for Semiconductors. Corrosion analysis was carried out via electrochemical impedance spectroscopy technique, and Cu(Ag) films demonstrated better resistance. Hardness tests also revealed that Cu(Ag) was approximately two times harder than Cu. Graphical Abstract: [Figure not available: see fulltext.]

    AtıfScopus6WoS6OpenAlex6
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2023Scopus SJRQ2
    ZrN and ta-C coatings on titanium for biomedical applications: Improved adhesion, corrosion, antibacterial activity, and cytotoxicity properties

    Aslan, Naim; Aksakal, Bünyamin; Cihangir, Salih; Cetin, Fadime; Yilmazer, Yasemin

    Commercially pure titanium (CP-Ti) is extensively used in biomedical applications. However, numerous qualities, including mechanical strength, corrosion resistance, and wear resistance, must be established for long-term performance as an implant material. This study investigates the enhancement of surface properties of CP-Ti through physical vapor deposition (PVD) with ZrN and ta-C (tetrahedral amorphous carbon). Among the coatings, ZrN revealed best overall results, such as adhesion, corrosion, microhardness, and wettability, excluding cell viability when compared to ta-C. E. coli and S. aureus were employed for antibacterial activity and MTS cell viability experiments. Compared to α-titanium, hardness tests revealed 91% increase in ZrN coating, and %22 increase in ta-C coating. Super-hydrophobicity and excellent antibacterial activity were found for ZrN coatings in comparison to ta-C. These findings emphasize the potential of ZrN and ta-C coatings to improve the surface properties of titanium, encouraging it to be used in biomedical devices. Graphical abstract: [Figure not available: see fulltext.].

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus16WoS16OpenAlex19
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ2
    Microstructure and corrosion investigation of FeCoCrNiMo0,5(MnAl)0,3 high entropy alloy produced by 316 L stainless steel scrap

    Cihangir, Salih; Say, Yakup; Ozkul, İskender; Guler, Omer; Guler, Seval Hale

    FeCrCoNiMo0,5(MnAl)0.3 high-entropy alloy (HEA) was manufactured via arc melting process by adding the related metal powders into scrap of 316 L stainless steel for corrosion resistance tests under salt and acid conditions. Cyclic potentiodynamic polarization experiments performed under acidic conditions revealed pre-passivation due to abundance of network modifying metals in HEA composition which was further analyzed by electrochemical impedance spectroscopy. Elemental resolved analysis of leftover solutions was used to compare metal ions released during corrosion. X-ray diffraction analysis indicated the phase change in heat treated HEA samples. Non-heat treated HEA samples can be compared with stainless steel under moderate corrosion conditions and had better hardness results.

    AtıfScopus20WoS17OpenAlex19
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2021Scopus SJRQ4
    Electrochemical Corrosion and Metal Ion Release Protective Efficiency of the Multilayer TaN Coatings on CoCrMo Biomedical Alloy

    Aslan, Ali Kemal; Bahçe, Erkan; Güler, Mehmet Sami

    CoCrMo alloy is widely used in artificial orthopedic joint applications due to its high mechanical properties. But, high levels of the metal ion release from alloy surfaces cause variable toxic and allergic effects on the patient in vivo use. This case restricts the lifetime of the implant and results in the failure of the artificial joint. In order to enhance the corrosion resistance and to decrease the metal ion release, alloy surface was multilayer-coated by closed field unbalanced magnetron system. The protective efficiency of the coatings was determined by potentiodynamic polarization tests and static immersion tests were performed for 45, 60 and 90 days in the simulated body fluid in order to understand the effect of the coatings on the metal ion release. The metal ion concentrations in the simulated body fluids were determined by using inductively coupled plasma mass spectrometry device. The electrochemical corrosion results showed that the multilayer coatings provided 93 % protective efficiency in terms of corrosion resistance. Multilayer coatings decreased the metal ions release levels significantly, especially Co leaking was decreased approximately 52 times compared to uncoated samples.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus2WoS3OpenAlex1
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2020Scopus SJRQ2
    The effect of graphene nano-sheet (GNS) weight percentage on mechanical and corrosion properties of AZ61 and AZ91 based magnesium matrix composites

    Guler, Omer; Say, Yakup; Dikici, Burak

    In this study, the effect of graphene nano-sheets (GNSs) on mechanical and corrosion properties of AZ61 and AZ91 based composites was investigated, detail. GNSs have been successfully produced by the liquid phase exfoliation (LPE) method and then, added AZ61 and AZ91 matrix with 01, 0.2, and 0.5 wt% GNSs for the production of the composites. The composite compacts were produced by powder metallurgy technique and sintered for 2 h at 500 °C under Ar atmosphere. The composite characterizations were carried out by scanning and transmission electron microscopes (SEM, TEM), electron dispersive spectroscope (EDS), Raman spectroscopy, and X-ray diffraction. The mechanical properties and corrosion behaviors of the composites have been compared with compression tests and potentiodynamic scanning (PDS) techniques, respectively. The results showed that the compressive strength of the composites increased with increasing GNS amount in both the AZ61 and AZ91 matrix alloys. The most susceptible composites to corrosion for both AZ61 and AZ91 matrix were observed in the 0.5 wt% GNS containing structures. However, there is a certain ratio of GNS in the Mg matrix to achieve good corrosion resistance.

    AtıfScopus29WoS25OpenAlex33
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2020Scopus SJRQ1
    Enhanced corrosion properties of biological NiTi alloy by hydroxyapatite and bioglass based biocomposite coatings

    Say, Y.; Aksakal, B.

    Enhanced corrosion resistance is always an obligatory property in biomedical applications. For this purpose, the surfaces of NiTi alloy were duplex coated both by Hydroxyapatite (HA)/Silver (Ag) and BioGlass (BG)/Silver (Ag) using the sol-gel method. The surface morphologies, and corrosion behaviours of the coatings were examined via SEM, EDS, XRD, and mechanically, by means of hardness as well as adhesion and corrosion tests. SEM analyses showed that the homogenous and crack-free structures were obtained in the biocomposite coatings. Spherical-like structures in the coatings were observed and pitting type of corrosion was formed in the biocomposite coated NiTi surfaces. After the corrosion tests, enhanced corrosion resistance was observed in both HA- and BG- based coatings. However, HA-based HA/Ag coatings on NiTi alloys were obtained to have higher adhesion strength as well as higher corrosion resistance compared to the BG-based biocomposite coatings. The findings in the present study can help the design of future implants with higher corrosion resistance.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus38WoS37OpenAlex42
    ScopusWeb of Scienceİncele